TY - JOUR
T1 - Time-frequency and complexity analyses for differentiation of physiologic murmurs from heart murmurs caused by aortic stenosis in Boxers
AU - Höglund, Katja
AU - Häggström, Jens
AU - Kvart, Clarence
AU - Ahlstrom, Christer
AU - Ask, Per
AU - Hult, Peter
PY - 2007
Y1 - 2007
N2 - Objective-To investigate whether time-frequency and complexity analyses of heart murmurs can be used to differentiate physiologic murmurs from murmurs caused by aortic stenosis (AS) in Boxers. Animals-27 Boxers with murmurs. Procedures-Dogs were evaluated via auscultation and echocardiography. Analyses of time-frequency properties (TFPs; ie, maximal murmur frequency and duration of murmur frequency > 200 Hz) and correlation dimension (T-2) of murmurs were performed on phonocardiographic sound data. Time-frequency property and T-2 analyses of low-intensity murmurs in 16 dogs without AS were performed at 7 weeks and 12 months of age. Additionally, TFP and T-2 analyses were performed on data obtained from 11 adult AS-affected dogs with murmurs. Results-In dogs with low-intensity murmurs,TIFF or T-2 values at 7 weeks and 12 months did not differ significantly. For differentiation of physiologic murmurs from murmurs caused by mild AS, duration of murmur frequency > 200 Hz was useful and the combination assessment of duration of frequency > 200 Hz and T-2 of the murmur had a sensitivity of 94% and a specificity of 82%. Maximal murmur frequency did not differentiate dogs with AS from those without AS. Conclusions and Clinical Relevance-Results suggested that assessment of the duration of murmur frequency > 200 Hz can be used to distinguish physiologic heart murmurs from murmurs caused by mild AS in Boxers. Combination of this analysis with T-2 analysis may be a useful complementary method for diagnostic assessment of cardiovascular function in dogs.
AB - Objective-To investigate whether time-frequency and complexity analyses of heart murmurs can be used to differentiate physiologic murmurs from murmurs caused by aortic stenosis (AS) in Boxers. Animals-27 Boxers with murmurs. Procedures-Dogs were evaluated via auscultation and echocardiography. Analyses of time-frequency properties (TFPs; ie, maximal murmur frequency and duration of murmur frequency > 200 Hz) and correlation dimension (T-2) of murmurs were performed on phonocardiographic sound data. Time-frequency property and T-2 analyses of low-intensity murmurs in 16 dogs without AS were performed at 7 weeks and 12 months of age. Additionally, TFP and T-2 analyses were performed on data obtained from 11 adult AS-affected dogs with murmurs. Results-In dogs with low-intensity murmurs,TIFF or T-2 values at 7 weeks and 12 months did not differ significantly. For differentiation of physiologic murmurs from murmurs caused by mild AS, duration of murmur frequency > 200 Hz was useful and the combination assessment of duration of frequency > 200 Hz and T-2 of the murmur had a sensitivity of 94% and a specificity of 82%. Maximal murmur frequency did not differentiate dogs with AS from those without AS. Conclusions and Clinical Relevance-Results suggested that assessment of the duration of murmur frequency > 200 Hz can be used to distinguish physiologic heart murmurs from murmurs caused by mild AS in Boxers. Combination of this analysis with T-2 analysis may be a useful complementary method for diagnostic assessment of cardiovascular function in dogs.
UR - https://res.slu.se/id/publ/15592
U2 - 10.2460/ajvr.68.9.962
DO - 10.2460/ajvr.68.9.962
M3 - Journal article
C2 - 17764410
SN - 0002-9645
VL - 68
SP - 962
EP - 969
JO - American Journal of Veterinary Research
JF - American Journal of Veterinary Research
IS - 9
ER -