Sammanfattning
This study analyses how the hydraulic performance differs between 13 ponds with hypothetically different layouts. The paper also includes a discussion of short-circuiting, hydraulic effciency and suitable parameters for measuring hydraulic performance. The ponds were studied by using a 2-D vertically integrated numerical model. Tracer studies were simulated and then evaluated and compared. The results confirm that length-to-width ratio, location of in-and outlets, and subsurface berm have a large impact on pond hydraulic performance. There is also an indication that an island placed in front of the inlet improves the hydraulic performance, and that a curved pond or an island placed near the side does not decrease the performance.
| Originalspråk | Engelska |
|---|---|
| Sidor (från-till) | 243-250 |
| Antal sidor | 8 |
| Tidskrift | Urban Water Journal |
| Volym | 2 |
| Nummer | 3 |
| DOI | |
| Status | Publicerad - 2001 |
| Externt publicerad | Ja |
Nyckelord
- hydraulics
- layout
- hydraulic performance
- numerical simulation
- ponds
- short-circuiting
- wetlands