Sammanfattning
An anaerobic digester (8 1) was fed with the organic fraction of municipal solid waste and monitored intermittently for two years with on-line near-infrared (NIR) spectroscopy and traditional chemical parameters analysed off-line. The dynamics that occurred due to changes in substrate composition (changed C:N ratio) and changes in operating conditions (overloading) could be followed using principal component analysis of the obtained NIR-spectra. In addition, process disturbances such as failed stirring and increased foaming were readily detected by the NIR-spectra. Using PLS regression the propionate concentration could be predicted in the range 0.1-3.6 g/l, RMSEP 0.53 g/l with slope 0.74 and correlation coefficient 0.85. The response on changes in the digester fluid was reproducible and could be detected within 2.5 minutes, which can be considered as real-time monitoring.
| Originalspråk | Engelska |
|---|---|
| Sidor (från-till) | 9-13 |
| Antal sidor | 5 |
| Tidskrift | Water Science and Technology |
| Volym | 48 |
| Nummer | 4 |
| DOI | |
| Status | Publicerad - 2003 |
| Externt publicerad | Ja |
Nyckelord
- biogas
- early warning
- MSW
- NIR
- on-line
- PCA
- PLS
- propionate