TY - JOUR
T1 - Improved maximum frequency estimation with application to instantaneous mean frequency estimation of surface electromyography
AU - Yu, Jun
AU - Stefan, Karlsson
AU - Nils, Östlund
PY - 2004
Y1 - 2004
N2 - The purpose of this study was to improve the maximum-frequency estimation. Three methods to estimate the maximum frequency of a bandlimited signal with additive white noise were compared. Two existing methods, the threshold-crossing method (TCM) and the hybrid method, were modified for time-frequency representations. A novel approach, the running-block threshold method (RBTM), was introduced. Based on calculation of detection probability (sensitivity) the RBTM improved the maximum-frequency estimate as compared with the TCM. The maximum-frequency estimation methods were also used to determine the integration interval for instantaneous mean-frequency (IMNF) estimation from synthesized surface electromyography containing white noise. Results showed that the IMNF estimate was improved by using any of the three methods and that the RBTM gave the best IMNF estimate.
AB - The purpose of this study was to improve the maximum-frequency estimation. Three methods to estimate the maximum frequency of a bandlimited signal with additive white noise were compared. Two existing methods, the threshold-crossing method (TCM) and the hybrid method, were modified for time-frequency representations. A novel approach, the running-block threshold method (RBTM), was introduced. Based on calculation of detection probability (sensitivity) the RBTM improved the maximum-frequency estimate as compared with the TCM. The maximum-frequency estimation methods were also used to determine the integration interval for instantaneous mean-frequency (IMNF) estimation from synthesized surface electromyography containing white noise. Results showed that the IMNF estimate was improved by using any of the three methods and that the RBTM gave the best IMNF estimate.
KW - electromyography (EMG)
KW - instantaneous mean frequency
KW - maximum frequency
KW - varying signal-to-noise ratio
KW - electromyography (EMG)
KW - instantaneous mean frequency
KW - maximum frequency
KW - varying signal-to-noise ratio
UR - https://res.slu.se/id/publ/4968
U2 - 10.1109/TBME.2004.827930
DO - 10.1109/TBME.2004.827930
M3 - Journal article
C2 - 15376502
SN - 0018-9294
VL - 51
SP - 1541
EP - 1546
JO - IEEE Transactions on Biomedical Engineering
JF - IEEE Transactions on Biomedical Engineering
IS - 9
ER -