Återgå till huvudnavigering Återgå till sök Gå direkt till huvudinnehållet

Bayesian evaluation of the accuracy of a thoracic auscultation scoring system in dairy calves with bronchopneumonia using a standard lung sound nomenclature

  • Antonio Boccardo
  • , Salvatore Ferraro
  • , Giulia Sala
  • , Vincenzo Ferrulli
  • , Davide Pravettoni
  • , Sebastien Buczinski

    Publikation: Bidrag till tidskriftArtikel i vetenskaplig tidskriftPeer review

    3 Nedladdningar

    Sammanfattning

    BackgroundAlthough thoracic auscultation (AUSC) in calves is quick and easy to perform, the definition of lung sounds is highly variable and leads to poor to moderate accuracy in diagnosing bronchopneumonia (BP). Hypothesis/ObjectivesEvaluate the diagnostic accuracy of an AUSC scoring system based on a standard lung sound nomenclature at different cut-off values, accounting for the absence of a gold standard test for BP diagnosis. AnimalsThree hundred thirty-one calves. MethodsWe considered the following pathological lung sounds: increased breath sounds (score 1), wheezes and crackles (score 2), increased bronchial sounds (score 3), and pleural friction rubs (score 4). Thoracic auscultation was categorized as AUSC1 (positive calves for scores & GE;1), AUSC2 (positive calves for scores & GE;2), and AUSC3 (positive calves for scores & GE;3). The accuracy of AUSC categorizations was determined using 3 imperfect diagnostic tests with a Bayesian latent class model and sensitivity analysis (informative vs weakly informative vs noninformative priors and with vs without covariance between ultrasound and clinical scoring). ResultsBased on the priors used, the sensitivity (95% Bayesian confidence interval [BCI]) of AUSC1 ranged from 0.89 (0.80-0.97) to 0.95 (0.86-0.99), with a specificity (95% BCI) of 0.54 (0.45-0.71) to 0.60 (0.47-0.94). Removing increased breath sounds from the categorizations resulted in increased specificity (ranging between 0.97 [0.93-0.99] and 0.98 [0.94-0.99] for AUSC3) at the cost of decreased sensitivity (0.66 [0.54-0.78] to 0.81 [0.65-0.97]). Conclusions and Clinical ImportanceA standardized definition of lung sounds improved AUSC accuracy for BP diagnosis in calves.
    OriginalspråkEngelska
    Sidor (från-till)1603-1613
    Antal sidor11
    TidskriftJournal of Veterinary Internal Medicine
    Volym37
    Nummer4
    DOI
    StatusPublicerad - 2023

    Bibliografisk information

    Publisher Copyright:
    © 2023 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals LLC on behalf of American College of Veterinary Internal Medicine.

    Nyckelord

    • calves
    • respiratory disease
    • thoracic auscultation
    • thoracic ultrasonography

    Citera det här