Återgå till huvudnavigering Återgå till sök Gå direkt till huvudinnehållet

A whole-tree chamber system for examining tree-level physiological responses of field-grown trees to environmental variation and climate change

  • Jan Parsby
  • , Sune Linder
  • , E Ceschia
  • , G Wallin
  • , J Medhurst
  • , M Slaney

Publikation: Bidrag till tidskriftArtikel i vetenskaplig tidskrift

Sammanfattning

A whole-tree chamber (WTC) system was installed at Flakaliden in northern Sweden to examine the long-term physiological responses of field-grown 40-year-old Norway spruce trees [Picea abies (L.) Karst.] to climate change. The WTCs were designed as large cuvettes to allow the net tree-level CO2 and water fluxes to be measured on a continuous basis. A total of 12 WTCs were used to impose combinations of atmospheric carbon dioxide concentration, [CO2], and air temperature treatments. The air inside the ambient and elevated [CO2] WTCs was maintained at 365 and 700 mu mol mol(-1), respectively. The air temperature inside the ambient temperature WTCs tracked air temperature outside the WTCs. Elevated temperatures were altered on a monthly time-step and ranged between +2.8 and +5.6 degrees C above ambient temperature. The system allowed continuous, long-term measurement of whole-tree photosynthesis, night-time respiration and transpiration. The performance of the WTCs was assessed using winter and spring data sets. The ability of the WTC system to measure tree-level physiological responses is demonstrated. All WTCs displayed a high level of control over tracking of air temperatures. The set target of 365 mu mol mol(-1) in the ambient [CO2] chambers was too low to be maintained during winter because of tree dormancy and the high natural increase in [CO2] over winter at high latitudes such as the Flakaliden site. Accurate control over [CO2] in the ambient [CO2] chambers was restored during the spring and the system maintained the elevated [CO2] target of 700 mu mol mol(-1) for both measurement periods. Air water vapour deficit (VPD) was accurately tracked in ambient temperature WTCs. However, as water vapour pressure in all 12 WTCs was maintained at the level of non-chambered (reference) air, VPD of elevated temperature WTCs was increased.
OriginalspråkEngelska
Sidor (från-till)1853-1869
Antal sidor17
TidskriftPlant, Cell and Environment
Volym29
Nummer9
DOI
StatusPublicerad - 2006

Nyckelord

  • Picea abies
  • elevated air temperature
  • elevated CO2
  • gas exchange
  • Norway spruce

Citera det här