TY - JOUR
T1 - Suspect screening and total oxidizable precursor (TOP) assay as tools for characterization of per- and polyfluoroalkyl substance (PFAS)-contaminated groundwater and treated landfill leachate
AU - Rehnstam, Svante
AU - Czeschka, Mai-Britt
AU - Ahrens, Lutz
N1 - Publisher Copyright:
© 2023 The Authors
PY - 2023
Y1 - 2023
N2 - Landfill facilities are a major source of release of per- and polyfluoroalkyl substances (PFAS) to the surrounding environment. In this study, landfill leachate treated in a conventional wastewater treatment plant and PFAScontaminated groundwater were subjected to suspect screening analysis and semi-quantification using total oxidizable precursor (TOP) assay and liquid chromatography coupled to high-resolution mass spectrometry (LCHRMS). TOP assays yielded expected results for legacy PFAS and their precursors, but showed no discernible evidence of degradation of perfluoroethylcyclohexane sulfonic acid. TOP assays also produced significant evidence of presence of precursors in both treated landfill leachate and groundwater, but the majority of precursors had probably degraded into legacy PFAS after many years in the landfill. Suspect screening identified a total of 28 PF AS, of which six were not included in the targeted method and were identified with confidence level (CL) ≥3. Semi-quantification of these six compounds showed very low concentrations, indicating that they are not as great a concern as the target PFAS.
AB - Landfill facilities are a major source of release of per- and polyfluoroalkyl substances (PFAS) to the surrounding environment. In this study, landfill leachate treated in a conventional wastewater treatment plant and PFAScontaminated groundwater were subjected to suspect screening analysis and semi-quantification using total oxidizable precursor (TOP) assay and liquid chromatography coupled to high-resolution mass spectrometry (LCHRMS). TOP assays yielded expected results for legacy PFAS and their precursors, but showed no discernible evidence of degradation of perfluoroethylcyclohexane sulfonic acid. TOP assays also produced significant evidence of presence of precursors in both treated landfill leachate and groundwater, but the majority of precursors had probably degraded into legacy PFAS after many years in the landfill. Suspect screening identified a total of 28 PF AS, of which six were not included in the targeted method and were identified with confidence level (CL) ≥3. Semi-quantification of these six compounds showed very low concentrations, indicating that they are not as great a concern as the target PFAS.
KW - High-resolution mass spectrometry
KW - Per- and polyfluoro alkyl substances
KW - Suspect screening
KW - Total oxidizable precursor assay
KW - High-resolution mass spectrometry
KW - Per- and polyfluoro alkyl substances
KW - Suspect screening
KW - Total oxidizable precursor assay
UR - https://res.slu.se/id/publ/127603
UR - https://www.sciencedirect.com/science/article/pii/S004565352301192X?via%3Dihub
U2 - 10.1016/j.chemosphere.2023.138925
DO - 10.1016/j.chemosphere.2023.138925
M3 - Journal article
C2 - 37187375
AN - SCOPUS:85160520481
SN - 0045-6535
VL - 334
JO - Chemosphere
JF - Chemosphere
M1 - 138925
ER -