TY - JOUR
T1 - Shape-selective extraction of PCBs and dioxins from fish and fish oil using in-cell carbon fractionation pressurized liquid extraction
AU - Haglund, P.
AU - Sporring, S.
AU - Wiberg, K.
AU - Björklund, E.
PY - 2007/4/1
Y1 - 2007/4/1
N2 - This paper describes a new shape-selective, pressurized liquid extraction (PLE) procedure for extracting polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and PCBs from food and feed samples wim an integrated carbon fractionation step. Initially this was done using specially designed inserts for 34-mL cells, but subsequently, large solid cells (66 mL) were machined to increase the capacity and robustness of the system. Depending on the carbon load and extraction solvent strength, the non-ortho PCBs were recovered either with the bulk of the PCBs or with the PCDD/Fs. The former is preferable if PCDD/Fs are the targets. In most cases, however, data are required for all indicator PCBs, WHO-PCBs, and PCDD/Fs. Therefore, further efforts focused on developing, optimizing, and validating a cost- and time-efficient PLE procedure that can extract these targets, separate non-ortho PCBs and PCDD/Fs from the bulk of the PCBs, allow gravimetric fat determinations, and requires a minimum of postextraction cleanup. The performance of the resulting procedure was assessed in experiments with a fish tissue reference material. The trueness of the WHO-PCB-TEQ, PCDD/F-TEQ, and total-TEQ data were -8, -5, and - 7%, respectively, and the corresponding CVs were 1.5, 0.5, and 1.3%; within the limits set by the European community for gas chromatography-high-resolution mass spectrometry methods for food and feed control.
AB - This paper describes a new shape-selective, pressurized liquid extraction (PLE) procedure for extracting polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and PCBs from food and feed samples wim an integrated carbon fractionation step. Initially this was done using specially designed inserts for 34-mL cells, but subsequently, large solid cells (66 mL) were machined to increase the capacity and robustness of the system. Depending on the carbon load and extraction solvent strength, the non-ortho PCBs were recovered either with the bulk of the PCBs or with the PCDD/Fs. The former is preferable if PCDD/Fs are the targets. In most cases, however, data are required for all indicator PCBs, WHO-PCBs, and PCDD/Fs. Therefore, further efforts focused on developing, optimizing, and validating a cost- and time-efficient PLE procedure that can extract these targets, separate non-ortho PCBs and PCDD/Fs from the bulk of the PCBs, allow gravimetric fat determinations, and requires a minimum of postextraction cleanup. The performance of the resulting procedure was assessed in experiments with a fish tissue reference material. The trueness of the WHO-PCB-TEQ, PCDD/F-TEQ, and total-TEQ data were -8, -5, and - 7%, respectively, and the corresponding CVs were 1.5, 0.5, and 1.3%; within the limits set by the European community for gas chromatography-high-resolution mass spectrometry methods for food and feed control.
UR - https://www.scopus.com/pages/publications/34247112802
UR - https://res.slu.se/id/publ/176f4ed3-c8bc-4770-ab40-1b892876ce83
U2 - 10.1021/ac0624501
DO - 10.1021/ac0624501
M3 - Journal article
C2 - 17343366
AN - SCOPUS:34247112802
SN - 0003-2700
VL - 79
SP - 2945
EP - 2951
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 7
ER -