Skip to main navigation Skip to search Skip to main content

Rapid and targeted HILIC-MS/MS quantification of urinary metabolites reveals metabolic alterations in COVID-19 patients

  • Ondrej Hodek*
  • , Anna Edman
  • , Christoffer Granvik
  • , Alicia Lind
  • , Anna K. Överby
  • , Mareike Gutensohn
  • , Annika I. Johansson
  • *Corresponding author for this work

Publication: Contribution to journal › Journal article › peer-review

Abstract

Urinary metabolites and their concentrations serve as biomarkers for identification of metabolic pathways that relate to specific diseases; therefore, fast and accurate quantification of the metabolites in urine is essential in health assessment and diagnosis. As many urinary metabolites are of polar nature, hydrophilic interaction liquid chromatography (HILIC) has been used over the last several years because it offers faster and more reproducible analyses compared to traditional techniques such as reversed-phase chromatography or capillary electrophoresis. In our study, we developed a HILIC method by using a 3 cm analytical column in connection with tandem mass spectrometry detection for quantification of 10 urinary metabolites including creatinine as the reference for normalization. As all tested metabolites contain ionizable functional groups, pH of the mobile phase was optimized to achieve baseline separation of 2 isomeric pairs (1-methyl-4-imidazoleacetic acid/1-methyl-5-imidazoleacetic acid and 1-methylhistidine/3-methylhistidine) and to obtain overall better separation efficiency resulting in a 7 min analysis. The developed method was validated in terms of sensitivity, carry-over, linearity, matrix effects, accuracy, and precision. The metabolite concentrations in healthy subjects determined by the developed method correspond well with the normal reference values found in the literature. Moreover, the method was tested on a small cohort of COVID-19 patients, where it enabled identification of differences in metabolite levels. Thus, the developed method has potential to be used routinely in a diagnostic field for high-throughput analysis of urine samples.

Original languageEnglish
Pages (from-to)5317-5323
Number of pages7
JournalAnalytical Methods
Volume18
Issue number25
DOIs
Publication statusPublished - 2 Jul 2026

Bibliographical note

Publisher Copyright:
This journal is © The Royal Society of Chemistry, 2026.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Cite this