TY - JOUR
T1 - Electrochemical impedance spectroscopy in label-free biosensor applications: multivariate data analysis for an objective interpretation
AU - Lindholm-Sethson, Britta
AU - Nyström, Josefina
AU - Malmsten, Martin
AU - Ringstad, Lovisa
AU - Nelson, Andrew
AU - Geladi, Paul
PY - 2010
Y1 - 2010
N2 - Electrochemical impedance spectroscopy plays an important role in biosensor science thanks to the possibility of finding specific information from processes with different kinetics at a chosen electrode potential in one experiment. In this paper we briefly discuss label-free impedimetric biosensors described in the literature. A novel method for neutral interpretation of impedance data is presented that includes complex number chemometrics. Three examples are given based on impedance measurements on synthetic biomembranes, in this case a lipid monolayer deposited on a mercury electrode. The interaction of various compounds with the monomolecular lipid layer is illustrated with the following: (1) different concentrations of magainin (Geladi et al. in Proc. Int. Fed. Med. Biomed. Eng. 9:219-220, 2005); (2) different derivatives of gramicidin A (Lindholm-Sethson et al. in Langmuir 24:5029-5032, 2007), and (3) an antimicrobial peptide (Ringstad et al. in Langmuir 24:208-216, 2008).
AB - Electrochemical impedance spectroscopy plays an important role in biosensor science thanks to the possibility of finding specific information from processes with different kinetics at a chosen electrode potential in one experiment. In this paper we briefly discuss label-free impedimetric biosensors described in the literature. A novel method for neutral interpretation of impedance data is presented that includes complex number chemometrics. Three examples are given based on impedance measurements on synthetic biomembranes, in this case a lipid monolayer deposited on a mercury electrode. The interaction of various compounds with the monomolecular lipid layer is illustrated with the following: (1) different concentrations of magainin (Geladi et al. in Proc. Int. Fed. Med. Biomed. Eng. 9:219-220, 2005); (2) different derivatives of gramicidin A (Lindholm-Sethson et al. in Langmuir 24:5029-5032, 2007), and (3) an antimicrobial peptide (Ringstad et al. in Langmuir 24:208-216, 2008).
KW - Impedance
KW - Biosensor
KW - Complex number chemometrics
KW - Impedance
KW - Biosensor
KW - Complex number chemometrics
UR - https://res.slu.se/id/publ/47806
U2 - 10.1007/s00216-010-4027-7
DO - 10.1007/s00216-010-4027-7
M3 - Review article
C2 - 20676616
SN - 1618-2642
VL - 398
SP - 2341
EP - 2349
JO - Analytical and Bioanalytical Chemistry
JF - Analytical and Bioanalytical Chemistry
IS - 6
ER -