Abstract
Two surface plasmon resonance (SPR)-based biosensor assays for detection of beta-lactam antibiotics in milk are reported. The assays are based on the enzymatic activity of a carboxypeptidase converting a 3-peptide into a 2-peptide, a reaction that is inhibited in the presence of beta-lactams. Antibodies were used to measure either the amount of formed enzymatic product or the amount of remaining enzymatic substrate. Both assays detected different beta-lactams at or below European maximum residue limits (MRLs), and the detection limit for penicillin G was 1.2 mug/kg and 1.5 mug/kg for the 2- and 3-peptide assays, respectively. The precision (CV) was < 5%, both within and between assays at the penicillin G MRL (4,mug/kg). The biosensor results obtained upon analysis of incurred milk samples were compared with results obtained by liquid chromatography (HPLC), and the method agreements were, in general, good.
| Original language | English |
|---|---|
| Pages (from-to) | 2791-2796 |
| Number of pages | 6 |
| Journal | Journal of Agricultural and Food Chemistry |
| Volume | 52 |
| Issue number | 10 |
| DOIs | |
| Publication status | Published - 2004 |
Keywords
- beta-lactams
- milk
- beta-lactam receptor protein
- SPR biosensor
Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver